TMP3200/090 DATASHEET
Doc. No. 37061 Rev. J 4 of 6
TMC090 Controller
Specifications. The TMC090 controller specifications are subject
to change without prior notice.
DIMENSIONS refer to TMC090 Mounting Drawing
RATING NEMA 1 (I.P. 30)
WEIGHT 2.15 kg ( 4.75 lb.)
OPERATING TEMP. 0° to 50°C (32° to 122° F), non-condensing
REQUIRED POWER 95-130 VAC, 2 amps, 50-60 Hz single phase
200-250 VAC, 1 amp, 50-60 Hz single phase
I/O VOLTAGE 12 to 24 VDC (customer-supplied)
TMC090 Mounting Drawing
Environmental Considerations. The following environmental
considerations must be taken into account when installing the
TMC090 controller.
Contaminants. The vented and fan-cooled TMC090 is rated
NEMA 1 (IP30). Accordingly, in environments where solid
and/or liquid contaminants are present, the possibility exists that
these contaminants can be drawn into the TMC090 controller
and possibly result in failure of a number of electronic
components. For that reason, in these types of environments, the
controller must
be located in a sealed industrial enclosure.
EMI Susceptibility. Although the system has been found to be
in compliance with pertinent susceptibility standards, care
should be taken when installing near welders and other extreme
generators of electromagnetic interference (EMI). Particular care
should be taken to ensure welder currents are not injected
through the marking head chassis. The marking head chassis is
connected to the electrical service earth ground through the
marking head cable. The marking head should be electrically
isolated from all surfaces which could become part of a welder
current path.